Adelphi Theatre
You are here: Home / Theatres / Adelphi Theatre / Technical Specifications
Email
 
Adelphi Theatre Auditorium

Adelphi Theatre Stage Door
Maiden Lane, London WC2E 7NN
Stage Door: 020 7836 1166  Manager: 020 7379 5723

Manager: Emma Sparks
NEAREST UNDERGROUND STATIONS Charing Cross/Embankment
SEATING CAPACITIES Stalls – 646
Dress Circle – 409
Upper Circle – 409
Box – 16
Wheelchair positions – 2Total: 1500 + 2 Wheel chair
STAGE  
Stage Finish 1” ply (25mm)
Rake None
Proscenium Opening 35’ (10m 82cm)
Height of Proscenium
Height to bottom of iron 22’ (6m 72cm)
Depth of Stage (from safety curtain) 32’ main + 20’ rear (9m 75cm main + 6m 8cm rear)
Distance from safety curtain to edge of forestage 2’ approx (60cm approx)
Height of Grid 60ft approx (18m 30cm approx)
Type of Grid Steel
Height of fly floors (to fly rail) 34’ approx (10m 36cm)
Distance between fly floors 45’ approx (13m 72cm approx)
Dock Door (Size and position) 9’ x 9’ rear above stage (2m 74cm x 2m 74cm rear above stage
Height of Stage from street 14’ 7” below street (4m 28cm below street)
Stage Trap OR Revolves None
Access to Stage U/S SR and U/S SL
Dimensions of all doors on get-in path None after get in doors only hump to cross
Hoist or Winches above get-in Electric Chain Hoist rated at 500KG
Wing space 6’ 8” approx each side (2m 10cm approx each side)
Cross over facilities Rear of stage and substage
ORCHESTRA PIT
How many musicians 20
Motorised No
FLYING SYSTEM
Number and position of counterweights sets 39 stage right
Number of hemp bars None permanent
Single or double purchase Both
Length of flying bars 41’ 10” (12m 80cm)
Cradle capacities 1500 lbs (685kg)
FoH Advance bars None
Height under fly floors 28’ (8m 68cm)
LIGHTING CONTROL
Position of lighting desk Enclosed rear upper circle
Type of desk No house desk
Number of dimmers 378
Follow spot position Rear of upper circle
Number of House Spots None
Best position for temporary dimmers High level dimmer room
POWER AVAILABLE
Position of Distribution Points: 400 TPN + 400TPN + 100 single phase for sound Stage dimmer room, high level dimmer room
SOUND POSITION Rear of stalls
COMMUNICATIONS 6 head sets and 12 cue lights (soft cue)
POSITION OF PROMPT CORNER Stage Left
DRESSING ROOMS 15
BAND ROOM FACILITIES 2
WARDROBE FACILITIES Wardrobe and wig room 2 washing machines
LICENSING AUTHORITY Westminster City Council
FRONT OF HOUSE FACILITIES
Number of bars and position 2 Stalls 1 Dress 1 Upper circle
VIP Rooms 1 Royal room, dress circle level
Kitchen available No
FACILITIES FOR DISABLED PEOPLE Ramp FoH 2 wheelchair positions Adapted toilet Infrared hearing aid system
AIR CONDITIONING Comfort cooling

 

© Copyright The Really Useful Group Ltd. 2012 | Privacy Policy and Cookies | Terms and Conditions | Help | About us | Contact us